Low Temperature Inverter Cooler
Features
- Up to 30% energy savings compared to existing equipment is possible.
- BLDC motor is applied to reduce the initial load at startup.
- Various operation modes can be implemented according to the site with the PLC program.
- Operating Temperature Max -40°C Cooling
※ When applied to a hydrogen filling station
- Gas-compressed hydrogen fuel technology was applied. Complies with SAE-2601-3 requirements.
Hyundai Nexo can charge 12 cars at 5.3 kg per hour / Bus can charge 2 cars at 25 kg per hour.
- low temperature inverter cooler
- Control Panel: *Optional by the orderer **For general sale
External View
Standard Specifications
Classification | Air Cooled Chiller | Water Cooled Chiller | ||||
---|---|---|---|---|---|---|
HDA-T4030-UL | HDA-T6030-UL | HDAI-T4030-UL | HDW-T4030-UL | HDW-T6030-UL | HDWI-T4030-UL | |
vehicle charging pressure | 35Mpa or 70Mpa | |||||
brine cooling temperature | 30°C ~ -60°C | 30°C ~ -60°C | 30°C ~ -40°C | 30°C ~ -60°C | 30°C ~ -60°C | 30°C ~ -40°C |
compressor capacity | 19kw x 19kw | 19kw x 26kw | 19kw | 19kw x 19kw | 19kw x 26kw | 19kw |
Circulation pump capacity | 4.5kw | 4.5kw | 4.5kw | 4.5kw | 4.5kw | 4.5kw |
brine pressure | 2.5~4Bar | 2.5~4Bar | 2.5~4Bar | 2.5~4Bar | 2.5~4Bar | 2.5~4Bar |
Refrigerant | R-507 | R-507 | R-410a | R-507 | R-507 | R-410a |
Power | 380/440/460-50Hz, 380/440/460-60hz | |||||
Power Consumption | 55kw | 63kw | 28kw | 55kw | 63kw | 57kw |
statutory frozen ton | 13.2RT | 17.25RT | 6.95RT | 13.2RT | 17.25RT | 6.95RT |
External dimensions | 1,950 x 3,800 x 2,150 | 1,950 x 3,800 x 2,150 | 1,350 x 2,600 x 2,150 | 1,950 x 3,800 x 1,750 | 1,950 x 3,800 x 1,750 | 1,350 x 2,600 x 1,750 |
- This product can be changed without notice according to techno logy development.